The 2-in-1 solution – 5-part diff and C-Reactive Protein
The HumaCount 5DCRP offers the possibility of simultaneous measurement of CRP and 5-part diff parameters out of one and the same sample.
The reduction in numbers of microscopy is the driving force in hematology. New parameters provided by the HumaCount 5DCRP like Large Immature Cells (LIC) and atypical Lymphocytes (ALY) help to reduce the manual workload by focusing on the confirmation of abnormal cells. The 3D-laser-scatter technology guarantees an excellent 5- part differentiation as required by clinicians. The ability to work with both venous and capillary blood samples, make the HumaCount 5DCRP a well-rounded instrument. The compact size and high throughput support the placement in both small and medium sized labs.
- Parallel detection of 5-part diff and CRP in a whole blood sample
- Direct capillary blood process by OptimalCount Technology
- Throughput: up to 60 samples per hour
- Sample volume: 20 μl
- 32 parameters with CRP
- 3D laser detection for improved 5-part differentiation
- Flexibility through a wide range of testing options (5-part, CRP and CBC)
- 2D barcode target value transfer
More information
Description | REF | Size |
---|---|---|
HC5D-Diluent | 16450/10 | 1 x 20 l |
HC5D-CBC-Lyse | 16450/20 | 1 x 200 ml |
HC5D-Diff-Lyse | 16450/30 | 1 x 500 ml |
HC5D-Clean | 16450/60 | 1 x 50 ml |
HC5D-Control | 16450/40 | 2 x 3 x 3 ml |
HC-Calibrator | 17400/50 | 1 x 2 ml |
CRP-Reagent Kit | 16451/70 | |
CRP-Control | 16451/40 | 1 x 75 ml, 1 x 25 ml |
CRP-Calibrator | 16451/50 | 3 x 1 ml |
End-to-End Capillaries 20 μl (100 pcs) | 16070/30 | 6 x 0,5 ml |
Description | REF |
---|---|
2D Barcode Reader | 16430/11 |
Portable battery system | 18965/220 |
Solar panel | 18965/100 |
Sample type | Human venous or capillary whole blood (K2 and K3-EDTA anticoagulant) Pre-Diluted blood |
Tube Identification | By means of the front panel keyboard (enter ID) By means of the barcode labels (optional) |
Sampling method | High precision syringe |
Measured parameters | 29 parameters: (on blood) RBC, MCV, HCT, RDW-SD, RDW-CV, HGB, MCH, MCHC, PLT, MPV, PCT, PDW, P-LCC, P-LCR WBC, LYM#, LYM%, MON#, MON%, NEU#, NEU%, EOS#, EOS%, BAS#, BAS%, ALY#, ALY%, LIC#, LIC% Distribution histograms: WBC, RBC, PLT 3 Dot-Plots (DIFF): LS-MS, LS-HS, HS-MS, , 1 Dot Plot (BASO) LS-MS 3 histograms for WBC, RBC and PLT 25 parameters: (on QC measurements) RBC, MCV, HCT, RDW-SD, RDW-CV, HGB, MCH, MCHC, PLT, MPV, PCT, PDW, P-LCC, P-LCR WBC, LYM#, LYM%, MON#, MON%, NEU#, NEU%, EOS#, EOS%, BAS#, BAS%, Distribution histograms: WBC, RBC, PLT 3 Dot-Plots (DIFF): LS-MS, LS-HS, HS-MS, , 1 Dot Plot (BASO) LS-MS 3 histograms for WBC, RBC and PLT |
Throughput | 60 samples/hour in CBC-Mode for whole blood 44 samples/hour in CBC+5Diff Mode for Capillary whole blood, Auto-Dispense, Capillary Tube (CTA) mode 45 samples /hour in CBC+5Diff Mode for venous whole blood 45 samples /hour in Pre-Diluted mode (CBC+5Diff) |
Measurement methods | Volumetric impedance change for RBC, PLT Colorimetric method for HGB 3D Light scattering WBC 4-diff measurement: LYM%, MON%, NEU%, EOS% 3D Light scattering BAS%, WBC measurement |
Aperture diameters | RBC/PLT: 70μm |